E.7 debug commands – KVH Industries TracVision 6 User Manual

Page 85

Advertising
background image

54-0166

90

TracVision 6 Technical Manual

Configure Longitude of a User-configurable Satellite

Function:

configures one of the user-configurable satellites
with the longitude provided

Command:

SATCONFIG,USERX,YYY,Z,D,L

Response:

If valid, echoes the input data
If invalid, returns error message

Where:

X = 1 or 2

YYY = longitude (0-180)

Z = E (East) or W (West)

D = decoding type (0 = test, 1 = DSS-A,

2 = DSS-B, 3 = DVB)

L = LNB polarization (C = circular, L = linear)

Set Saved Satellite Position

Function:

sets saved satellite position

Command:

GOTO,AZXXXX,ELYYY

Response:

SAVED SAT POS: AZ = XXXX, EL = YYY

Where:

XXXX = azimuth (0000 - 3599)

YYY = elevation (100 - 850)

E.7

Debug Commands

Enter Debug Mode

Function:

enters Debug mode

Command:

DEBUGON

Response:

echoes the command, system enters Debug mode

Limit Switch Test

Function:

performs a limit switch test

Command:

=LSTEST

Response:

Limit Switch Status: PASS

Set/Report Offset Angles

Function:

reports or sets system offset angles

Command:

OFFSETS

OFFSETS,XXXXX,YYYY

Response:

Offsets = XXXXX.X YYYYY.Y

Where:

X = azimuth offset (-1800 - 1800)

Y = elevation offset (-450 - 450)

Table E-7

Debug Commands

Advertising