TROUBLESHOOTING

E-6

CLASSIC I

LINCOLN

ELECTRIC

ELECTRIC

®

ELECTRONIC IDLER TROUBLESHOOTING GUIDE

Engine Will Not Return to Idle

in Approximately 15 Seconds

Set Idler Control Switch

to the Auto Position

Check to See Whether Oil Pressure

Light is On and Alternator is Charging

Light Off

Light On

If Oil Light is O.K., Replace Oil

Check Continuity of Idler

Pressure Switch

Control Switch

The Arc is Struck

Reed Switch in Weld Circuit

Defective -- Will Not Close

To Check: Short the Red Lead

on P.C. Board to Welder Frame.

The Auxiliary Power Load is Turned On

Power Load Too Small

Try Load Above 150 Watts

Engine Does Not Pick Up Speed

Check Connections and Continuity of

Current Transformer.

Replace P.C. Board

Engine Picks Up Speed

When Arc is Struck

1. Replace Reed Switch

in Weld Circuit.

Engine Does Not Pick

Up Speed

Replace P.C. Board

Engine Will Not Pick Up Speed When:

Continuity Good

1. Reed switch in weld circuit

may be stuck closed.

2. Check continuity of idler

solenoid coil (25 ohms).

3. Replace P.C. Board.

Open

Replace Switch