MAINTENANCE

D-2

D-2

LN-25™ PRO

ELECTRIC SHOCK can kill.

• Do not operate with covers

removed.

• Turn off power source before

installing or servicing.

• Do not touch electrically hot

parts.

• Turn the input power to the welding power

source off at the fuse box before working in the
terminal strip.

• Only qualified personnel should install, use or

service this equipment.

----------------------------------------------------------------------

WARNING

SAFETY PRECAUTIONS

ROUTINE MAINTENANCE

• Check weld cables and gas hoses for cuts.
• Clean and tighten all weld terminals.

PERIODIC MAINTENANCE

• Clean drive rolls and inner wire guide and replace if

worn.

• Blow out or vacuum the inside of the feeder.

CALIBRATION SPECIFICATION

The voltmeter and flow meter are not calibrated and
are for reference purposes only.

Voltmeter Validation, Across the Arc Analog Meter
Models

Tools required:

• DC voltmeter reference standard
• Constant voltage DC welding power source with

adjustable no-load voltage (DC-400, V-350, CV-400
or equivalent).

To verify the analog voltmeter accuracy:

1. Turn power OFF.

2. Connect the LN-25™ PRO to the constant voltage

DC welding power source. The work lead of the
LN-25™ PRO must be connected to the work ter-
minal of the power source.

3. Connect the reference voltmeter between the brass

block of the LN-25™ PRO and the work lead.

4. Turn power ON.

5. Energize the output circuit of the power source.

Adjust the power source output to 20±1 VDC as
measured on the reference meter.

6. Verify that LN-25™ PRO voltmeter reads between

19 and 21 volts.

If the voltmeter reading is out of range, check for loose
connections or replace the voltmeter. There is no cal-
ibration adjustment for the LN-25™ PRO voltmeter.

Flow Meter Validation

Tools required:

• Flow meter reference standard.
• Constant voltage DC welding power source (DC-

400, V-350, CV-400 or equivalent).

To verify the flow meter accuracy:

1. Turn power OFF.

2. Connect the LN-25™ PRO to the constant voltage

DC welding power source. The work lead of the
LN-25™ PRO must be connected to the work ter-
minal of the power source.

3. Connect a supply of CO2 to the wire feeder. Do not

exceed the maximum inlet pressure of the wire
feeder.

4. Disconnect the shielding gas hose that connects to

the gun bushing.

5. Connect the shielding gas hose to flow meter refer-

ence standard.

6. Orient the LN-25™ PRO in a vertical position.

7. Turn power ON.

8. Adjust the flow meter on the LN-25™ PRO to 40

scfh while pressing the GAS PURGE button.

9. Measure the gas flow with the calibrated flow meter

while pressing the GAS PURGE button.

10. The measured flow rate should be between 35

and 45 scfh.

The LN-25™ PRO flow meter cannot be calibrated. If
the flow meter reads incorrectly, check for leaks or
kinks in the gas hose. Replace the flow meter if neces-
sary.

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

Advertising