Troubleshooting & repair, Case control box assembly, Motor overload test (continued) – Lincoln Electric LN-25 SVM179-B User Manual

Page 62

Advertising
background image

CASE

CONTROL BOX ASSEMBLY

FIGURE F.5 – CONTROL BOX ASSEMBLY

MOTOR OVERLOAD TEST (CONTINUED)

PROCEDURE

1. Perform the Case Removal Procedure.

2. Remove the 5 #10-24 x .50 screws holding

the control box cover to access the contactor
leads. See Figure F.2.

3. Remove the five #10-24 screws holding the

control box cover, and locate the two motor
leads and 3 tach leads. See the Wiring
Diagram
.

4. Apply the correct input voltage (15-110vdc) to

the unit.

5. With the trigger activated and the motor run-

ning check the motor armature current.
Normal armature current is less then 3 amps.

6. If the amperage exceeds 3.2 amps for more

than 8 seconds the motor will be disabled.

7. If the motor armature current is normal and

the motor still shuts down the control board
may be faulty.

8. If the current is high check for restrictions in

the feed system. They can be caused by a
clogged liner, spindle tightness, drive rolls to
tight, fault drive motor or a faulty gearbox.

9. After testing replace faulty parts and reassem-

ble the feeder in reverse order of disassembly.

TROUBLESHOOTING & REPAIR

F-18

F-18

LN-25™ PRO

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

Advertising