Installation – Lenoxx Electronics Optima 3 FS User Manual

Page 19

Advertising
background image

INSTALLATION

USA & Canada – Requires an approved noncombustible hearth or floor protector, 3/8” / (10 mm) millboard

or equivalent (k = .84, r = 1.19) to extend 6” / 150 mm to the front of the glass door.

PAGE 19

Standard Vertical Installation Configurations
Models:
Optima 2 FS and Optima 3 FS
These freestanding models may be connected to an
existing flue or by installing listed type “PL” vent pipe. If
a liner is run all the way to the top of the existing chim-
ney, the existing flue should be sealed with a steel
plate. Start a vertical run with a Tee at the back of the
stove. Other options are illustrated below. Note: See
page 15 for Vent Termination Requirements

Exterior Vertical Vent

Vertical Vent Into A Masonry Flue

Preferred Installation – Vertical Vent Through the

Roof

This venting configuration allows for the best stove
performance. The vertical pipe promotes natural draft
and with the chimney inside the dwelling, the flue
gases stay warm, thus rising at a consistent rate.

Interior Vertical Vent into an

Existing Class A Chimney

Wall Straps
Required Every
4 ft. Minimum

Optional Com-
plete Liner and
Listed Termina-
tion Cap

Optional Clean-Out
Access Door

Listed Rain Cap

3”

Min.

Clean-Out
Tee

Existing
Chimney
Pipe

Extend Pipe to
the Top if Exist-
ing Chimney is
Corroded or
Damaged

Pipe Increaser

3”

Min.

Flashing