PLANNING YOUR INSTALLATION

PAGE 5

FLOOR PROTECTION - Optima 2 FS

This appliance requires noncombustible floor protec-
tion. If the floor protection is to be stone, tile, brick, etc.,
it must be mortared or grouted to form a continuous
non-combustible surface. If a chimney connector ex-
tends horizontally over the floor, the protection must
cover the floor under the connector and at least 2" to
either side.

A noncombustible floor protector must fully cover the
area beneath the appliance and extend 6” to the front,
6” to the sides, and up to 6" from the back as illus-
trated on this page.

*Note: When installed at clearances less than 6”, floor pro-
tection is only required to extend to the wall.

Top View of Model: Optima 2 FS

Up to * 6"/153mm
minimum

6"/

153mm

min..

6"/

153mm

min.

Rear

Front

6"/

153mm

min.