Planning your installation – Lenoxx Electronics Optima 3 FS User Manual

Page 9

Advertising
background image

PLANNING YOUR INSTALLATION

PAGE 9

Models – Optima 2 FS and Optima 3 FS



MANUFACTURED (MOBILE) HOME INSTALLATION
Freestanding Models – Optima 2 FS and Optima 3 FS
In addition to the standard installation instructions, the
following instructions may be required by local, state or
federal building codes:
• Stove must be permanently bolted to the floor.
• An outside air inlet must be provided for combustion

and be unrestricted while unit is in use. Use a galva-
nized or stainless steel pipe for the duct (the outside
air inlet on the stove is 2" diameter).

• Stove must be permanently electrically grounded to

the steel chassis of the home. The location selected
for ground attachment to the stove must be dedicated
for this purpose.

• See pages 14 through 19 for additional information on

venting requirements.

• Do not install appliance in a sleeping room.
• The structural integrity of the manufactured home

floor, walls, ceiling and roof must be maintained.


NOTE: The grounding of this product, at installation,
must comply with NFPA-70 standards, CSA C22.1 in
Canada, as well as any local codes.

MANUFACTURED (MOBILE) HOME EXHAUST VENT
PIPE INSTALLATION GUIDELINES
Use only listed type “PL” pellet vent pipe. Pipe should
extend at least 3 feet above the part of the roof through
which it passes. The top of the pipe should be at least 2
feet above the highest required elevation of any part of
the manufactured (mobile) home within 10 feet of the
pipe.

If the exhaust vent exits the manufactured (mobile)
home at a location other than the roof, and exits at a
point 7 feet or less above the ground level on which the
manufactured (mobile) home is positioned. A guard or
method of enclosing the pipe shall be provided at the
point of exit for a height of up to 7 feet. The openings, if
any, in this guard shall not allow a 3/4” rod to pass
through. A 1/2” rod could pass through but should not
be able to touch the pipe when inserted through the
opening a distance of 4 inches.

Bolt

Floor Protector

Floor

Chassis

Ground to Steel Chassis

Advertising