ROUTINE MAINTENANCE

* Inspect your stove or insert at minimum frequency stated until you establish a minimum frequency required for
your installation (frequency will vary depending upon fuel BTU value / ash content, usage, and misc. installation
variables). Unplug and Ensure Stove is Cold Before Performing Any Maintenance Work. Include routine mainte-
nance with annual maintenance. The following areas need to be inspected and cleaned as part of annual main-
tenance:

PAGE 28

ROUTINE CLEANING

Unplug and Ensure Stove is Cold Before Performing
Any Maintenance Work.

The following areas need to be inspected and cleaned
during Routine Cleaning:
• UltraGrate (burn grate)
• Ash Pan
• Heat Exchange Tubes / Tube Scraper
• Photoeye
• Exhaust Passages and Vent Pipe
• Ash Clean-out Ports
• Gaskets
• Window Wash
• Rear Stove / Insert Compartment

UltraGrate

(Burn Grate for All Models)

The UltraGrate

 should be inspected periodically to as-

sure that the air holes have not become clogged with ash
or clinkers. The UltraGrate

 can easily be cleaned with

the grate scraper / ash pan tool, or it can be removed for
cleaning. It is very important to monitor the ash build up
under the UltraGrate

, as excessive amounts of ash will

block combustion air from entering the grate, causing
pellets to pile-up in the grate. The grate cleaning proce-
dure is the same for all models.

UltraGrate

* (Minimum Frequency of 1 day to 2 weeks)

ASH PAN (Optima 2 FS and Optima 3 FS)

All ash removal and cleaning should be done while
stove is cold.

The ash pan will have to be emptied periodically, depend-
ing on the amount of fuel consumed. To access follow
steps one through four:
1. Open the glass door, then, using the ash pan / grate

scraper tool, lift the UltraGrate® out and sweep the
top ash into the pan below.

2. Remove the ash pan cover located below the door by

pulling forward until magnets release.

Models Optima 2 FS and Optima 3 FS

Model Optima 3 INS


Ash Pan
Cover

UltraGrate

Ash Pan
Cover

Optima 3 INS has a
handle on the exterior
of the ash pan cover for
easy access and re-
moval.

* (Recommended Frequency of 2 days – 2
weeks)