Troubleshooting, Caution – Lincoln Electric IDEALARC R3R 600-I User Manual

Page 16

Advertising
background image

E-3

TROUBLESHOOTING

E-3

IDEALARC R3R 600-I

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDED

COURSE OF ACTION

C. Machine input contactor closes

but has no or low output. Open
circuit voltage should be 67 to 71
volts.

D. Machine has maximum output

but no control.

1. Electrode or work lead loose or

broken.

2. Open transformer primary or

secondary circuit.

3. Supply line fuse blown.

4. Input line grounded causing

single phase input.

5. Input leads not connected to

contactor.

6. Latching resistor, R3, open.

7. Control circuit problems.

1. Possible defective power SCR.

2. Possible defective control board.

1. Repair connections.

2. Repair.

3. Replace blown fuse – check fuse

size.

4. Repair input to machine.

5. Connect input lead.

6. a. Replace.

b. Check leads to the resistor

and repair if defective.

7. See Troubleshooting Procedures

– Power Silicon Controlled
Rectifier.

1. Remove all gate leads G1, G2

and G3 at PC board connector
J4. If welder has any open circuit
voltage, power SCR is defective.
See Troubleshooting Procedures
Section J.

2. See PC board Troubleshooting

Procedures Section A