Installation – Lincoln Electric IDEALARC R3R 600-I User Manual

Page 8

Advertising
background image

A-1

INSTALLATION

IDEALARC R3R 600-I

A-1

TECHNICAL SPECIFICATIONS – R3R 600-I K1381-[ ]

Volts at Rated Amperes

35
40
44

Amps

375
500
600

Duty Cycle

100%

60%
35%

INPUT - THREE PHASE ONLY

OUTPUT

Insulation Class: 155°C (F)

Standard Voltage Frequency

220-230V/50/60Hz
380-400V/50/60Hz
440-460V/50/60Hz

11.3@220V/50Hz

.74 @ 500A

Rated Input Current

103A @ 600A Output

92A @ 500A Output
68A @ 375A Output

(220V/50/60Hz)

(Volts/Hz)

DC RATED OUTPUT

PHYSICAL DIMENSIONS

HEIGHT

27.5 in
699 mm

WIDTH

22.3 in
566 mm

DEPTH

32.0 in
813 mm

WEIGHT

446 lbs.

203 kg.

Current Range

75-625 Amps

}

Maximum Open Circuit Voltage

64VDC

TEMPERATURE RANGES

POWER FACTOR @ RATED LOAD

IDLE CURRENT

OPERATING TEMPERATURE RANGE

-40°C to +40°C