Wiring diagrams, L9376, B.01 – Lincoln Electric IDEALARC R3R 600-I User Manual

Page 24

Advertising
background image

F-1

WIRING DIAGRAMS

F-1

IDEALARC R3R 600-I

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The

specific diagram for a particular code is pasted inside the machine on one of the enclosure panels.

ELECTRICAL SYMBOLS PER E1537

LEGEND

D5

D6

D7

POCKET AMPTROL SENSING BRIDGE

L1

DC OUTPUT FILTER

R1

R2

R3

R4

16

TO SUPPLY LINES

TO GROUND

PER

NATIONAL

ELECTRICAL

CODE

1

2

3

L1

L2

L3

ICR

233

232

231

H3

H2

H1

X2

X1

T2

RECONNECT PANEL SHOWN

CONNECTED FOR LOW VOLTAGE

4

5

6

7

8

9

1

2

3

232

231

H3

H2

H1

X2

X1

T2

233

TO GROUND

PER

NATIONAL

ELECTRICAL

CODE

ICR

L1

L2

L3

TO SUPPLY LINES

TO GROUND

PER

NATIONAL

ELECTRICAL

CODE

H3

H2

H1

X2

X1

T2

TO SUPPLY LINES

TO GROUND

PER

NATIONAL

ELECTRICAL

CODE

232

231

H3

H2

H1

X2

X1

T2

TO SUPPLY LINES

ICR

233

TO PRIMARY

COILS

PRIMARY CONNECTIONS

MAIN TRANSFORMER

1

2

3

L1

L2

L3

DIAL SELECTOR SWITCH

SCR1-D1

SCR2-D2

SCR3-D3

D4

SCR AND DIODE

RECTIFIER BRIDGE

T1

T2

T3

MAIN TRANSFORMER

CONTROL TRANSFORMER

POCKET AMPTROL OPTION

TRANSFORMER

ICR

INPUT STARTER

( DASHED ITEMS ON WIRING

DIAGRAM ARE OPTIONAL )

CAVITY NUMBERING SEQUENCE

(COMPONENT SIDE OF BOARD)

A

B

C

D

E

F

10K OHM POT., OUTPUT CONTROL

10K OHM POT., ARC FORCE CONTROL

40 OHM

SW1

SW2

SW3

SW4

POWER SWITCH

MACHINE/REMOTE SWITCH

L1

D4

D1

D2

D3

SCR1

SCR2

SCR3

R3

204

204

204

205

206

SHUNT

218

R4

D5

D6

D7

219

219

201

202

203

204

204
209
208

217

CONTROL

P.C.

BOARD

SW1

PILOT LIGHT

231

235

235

232

W

THESE LEADS ARE
PRESENT ONLY WITH
OPTIONAL METER
KIT.

220
225

115V

G

G

Y

T3

G

OPTIONAL POCKET

AMPTROL P.C.

BOARD

77

76

75

75

217

206

205

204

204

214

75

210 211

R1

SW2

R2

204

208

209

224

OPTIONAL METER KIT

VM

AM

+

+

-

-

TO CONTROL BOX

-

+

217

217

A

A

115 V

201

202

203

7

S

S

10

1

4

5

6

66V

BOTTOM PRIMARY

TOP PRIMARY

T1

X1

X2

X3

SEC

SEC

SEC

16, 17, & 18 ARE PRESENT

ON 380/500 OR 460/575

MACHINES ONLY.

THERE IS NO 10-11-12

CONNECTION ON 380,

A

CHOKE

THERMOSTAT

SECONDARY

THERMOSTAT

233

231

204

ICR

1

2

3

L1

L2

L3

RECONNECT PANEL SHOWN

CONNECTED FOR 220V

H4

234

235

FAN MOTOR

HIGH TEMP LIGHT

221

222

223

G1 G2 G3

204

+

-

G1 G2 G3 204

226

220

204

211

210

213

77

212 76

SW3

A = AMBER

G = GREEN

W = WHITE

Y = YELLOW

COLORS

235

232

ARE MADE AT THE

SINGLE, 346V AND ABOVE

(EXCEPT 380V.)

220/380/440

SINGLE, BELOW 346V OR

DUAL VOLTAGE

380/500 OR 460/575

76

77

SW4

RECONNECT PANEL SHOWN

CONNECTED FOR LOW VOLTAGE

1
2
3
4
1
2
3
4
5
6

77

76

75

G

Y

218
219

J6

J7

1
2
3
4
5
6
7
8

214
75

213

212

201A

203A

J2

J4

201A

203A

J3

6

3

2

1
5

1

8

5

6

7

4

3

2

1

5

6

4

3

2

1

2

4

3

1

2

J1

.4 OHM POCKET AMPTROL SENSING RESISTOR

CONNECTOR AND THESE THREE

LEADS ARE NOT USED WHEN

OPTIONAL POCKET AMPTROL

IS PROVIDED.

4

2 1 3 4

2 1

RECTIFIER

BRIDGE

1 2 3 4 5 6 7 8

J5

SNUBBER BOARD

226

224

204

235

TO PRIMARY

COILS

TO PRIMARY

COILS

TO PRIMARY

COILS

231

233

(SWITCH SHOWN IN LOCAL POSITION)

220/380/440 OR

230/400V MACHINES.

REMOTE CONTROL RECEPTACLE

2

3

16

17

18

11

8

66V

S

66V

9

12

OPTIONAL POLARITY SWITCH

(60 Hz ONLY)

11

10

12

6

4

5

7

8

9

TO GROUND

PER

NATIONAL

ELECTRICAL

CODE

1

2

3

L1

L2

L3

ICR

233

232

231

H3

H2

H1

X2

X1

T2

TO SUPPLY LINES

RECONNECT PANEL SHOWN

TO PRIMARY

COILS

CONNECTED FOR 230V

230/400V

PRIMARY CONNECTIONS 1-7, 2-8 AND 3-9

ARE MADE AT THE MAIN TRANSFORMER

PRIMARY CONNECTIONS 4-7, 5-8 AND 6-9

ARE MADE AT THE MAIN TRANSFORMER

17

18

4-7, 5-8 AND 6-9

AUXILIARY COILS

(ON BOTTOM PRI.

COIL ASSEMBLIES)

L9376

B.01

IDEALARC R3R-400, 500-I, 500 & 600-I WIRING DIAGRAM

4

5

6

9

8

7

11

TO PRIMARY COILS

10

12

FLEX
LEAD

JUMPER

RECONNECT PANEL

A

A

A

A

INPUT BOX

LIFT BALE

CONTROL

CONTROL

BOX

AND FRAME

PANEL

REMOTE

RECEPTACLE

BONDED GROUNDING LEADS

(R3R-600-I ABOVE CODE 11200 ONLY)

AND

220-230/380-

400/440-460

GROUNDING STUD

Advertising