TROUBLESHOOTING

E-5

IDEALARC R3R 600-I

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDED

COURSE OF ACTION

H. Machine trips off when under no

load or makes excessive noise
like it is loaded.

I. Variable or sluggish welding arc.

J. Welder will not shut off.

K. Current control on machine not

functioning.

1. Power bridge rectifier may have

a shorted diode or SCR.

2. Short in the transformer.

3. Fan hitting vertical baffle.

1. Poor work or electrode cable

connection.

2. Current too low.

3. Welding leads too small.

4. Open SCR or diode in power

rectifier bridge.

5. Control circuit problems.

1. Input contactor contacts frozen.

1. Current control switch in wrong

position.

2. Current control switch defective.

3. Current control potentiometer

defective.

4. Lead or connection in control

circuit open.

5. Defective control or circuit

boards.

1. Refer to Power Hybrid,

Troubleshooting Procedures,
Section J and Snubber, Section
F.

2. Repair.

3. Clear the fan.

1. Check and clean cable connec-

tions.

2. Check recommended currents

for rod type and size.

3. See Table in Output Connection

Section.

4. Check per Power Rectifier

Bridge Troubleshooting
Procedures, Section J and
Snubber, Section F.

5. See SCR Troubleshooting,

Section K.

1. Replace input contactor.

1. Place switch in “machine” ( I )

position.

2. Check per Section H.

3. Check per Section G.

4. Repair or connect.

5. See SCR Troubleshooting,

Section K.