INSTALLATION

Line Cord Connection

A 3 conductor line cord with a 50 amp, 250 volt, three-
prong plug (NEMA Type 6-50P) is factory installed.
Connect this plug to a mating grounded receptacle
which is connected to an appropriate power supply
per the U.S. National Electric Code and any applicable
local codes.

CONNECT TO A SYSTEM
GROUNDING WIRE. SEE
THE UNITED STATES
NATIONAL ELECTRICAL
CODE AND/OR LOCAL
CODES FOR OTHER
DETAILS AND MEANS FOR
PROPER GROUNDING.

CONNECT TO HOT WIRES
OF A THREE-WIRE SINGLE
PHASE SYSTEM OR TO
ONE PHASE OF A TWO OR
THREE PHASE SYSTEM.

This welding machine must be connected to a
power source in accordance with applicable elec-
trical codes.

The United States National Electrical Code (Article
630-B, 1990 Edition) provides standards for
amperage handling capability of supply conduc-
tors based on duty cycle of the welding source.

If there is any question about the installation
meeting applicable electrical code requirements,
consult a qualified electrician.

ELECTRICAL INPUT CONNECTION FOR
RATED OUTPUT

ELECTRIC SHOCK can kill.

• Disconnect input power by removing

plug from receptacle before working
inside SP-175 Plus.

• Use only grounded receptacle.

• Do not touch electrically “hot” parts

inside SP-175 Plus.

• Have qualified personnel do the main-

tenance and troubleshooting work.

230 Volt Input Connection

The SP-175 Plus is shipped from the factory connect-
ed for 230 volt input power. If the welder has been
reconnected for 208 volt input power and 230 volt
input is desired, perform the following reconnection
instructions:

1. Disconnect welder from input power and remove

case side panel.

2. Remove lead marked “H3” from H1 terminal on the

control P.C. Board.

3. Remove tape securing H1 lead to lead sleeving

and connect H1 lead to H1 terminal on the board.

4. Insulate unused H3 lead for 300 volts with electri-

cal tape and secure to lead sleeving.

5. Reinstall case side before connecting input power.

208 Volt Input Connection

1. Disconnect welder from input power and remove

case side.

2. Remove lead marked “H1” from H1 terminal on the

control P.C. Board.

3. Remove tape securing H3 lead to lead sleeving

and connect H3 lead to H1 terminal on the board.

4. Insulate unused H1 lead for 300V with electrical

tape and secure to lead sleeving.

5. Reinstall case side before connecting input power.

WARNING

Grounding

Type 75°C

Wire

Fuse

Wire in Conduit,

Copper

Size

Input

Copper Cond.

Cond.

(Super

Voltage

Hertz

AWG Size

AWG Size

Lag)

208/230

60

8

10

40

WARNING

SP-175 PLUS