Troubleshooting, Caution – Lincoln Electric IM610-A User Manual

Page 43

Advertising
background image

E-4

SP-125 PLUS

E-4

TROUBLESHOOTING

Observe Safety Guidelines detailed in the beginning of this manual.

If for any reason you do not understand the test procedures or are unable to Perform the tests/repairs safely, contact your
LOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY for assistance before you proceed.

CAUTION

PROBLEMS
(SYMPTOMS)

Arc is unstable – Poor starting

POSSIBLE AREAS OF
MISADJUSTMENT(S)

1. Check for correct input voltage

to machine – 208 or 230 VAC.

2. Check for proper electrode

polarity for process.

3. Check gun tip for wear or dam-

age – Replace.

4. Check for proper gas and flow

rate for process.

5. Check work cable for loose or

faulty connections.

6. Check gun for damage or

breaks.

7. Check wire feed to assure

smooth wire feeding (check
brake adjustment).

RECOMMENDED
COURSE OF ACTION

Contact your local Lincoln
Authorized Field Service Facility.

WELDING PROBLEMS