F-1

SP-175 PLUS

F-1

WIRING DIAGRAMS

M19060

L1

L2

31

H2

202

201

D5

D7

D2

D8

204

204

203

203

203

204

-

+

OUTPUT CHOKE

TO

WORK

ELECTRICAL SYMBOLS PER E1537

CIRCUIT

BREAKER

31A

12

3

45

6

LATCH

FAN

MOTOR

1

234

LATCH

5

6

789

1

0

J1

J2

CAVITY NUMBERING SEQUENCE

12

3

4

56

123

4

5

6

7

89

1

0

7

32A

CONTROL P.C. BOARD

539

541

207

205

206

541

539

203

204

210

209

213

208

211

T1

WIRE FEED MOTOR

213A

GUN TRIGGER

THERMOSTAT

(MOUNTED TO

DIODE HEATSINK)

+

208

209

210

5K

WIRE SPEED

205

206

207

5K

( J1 )

( J2 )

*

*

*

CONNECTOR CAVITY NUMBER

ARC VOLTAGE

R1

R2

7

32A

N.A.

N.C.

N.C.

N.D.

24 VAC

AUX WDG.

NOTES:

N.C. COMPONENT VIEWED FROM REAR.

HIGH VOLTAGE

can kill

Only qualified persons should install, use or

service this machine.

Do not operate with covers removed.

Do not touch electrically live parts

Disconnect input power by unplugging

power cord before servicing

WHICH IS CLOSEST TO THE CENTER PANEL.

N.B., N.D.

(COMPONENT SIDE OF BOARD)

N.D. BOLTED ALUMINUM CONNECTIONS REQUIRE T12837 JOINT

COMPOUND (DOW CORNING 340) WHEN REATTACHING.

SP-175 Plus

WIRING DIA

GRAM CODE 10542

1

2

3

4

5

LATCH

J3

5

4

32

1

JUMPERED PLUG STANDARD

SPOT/STITCH TIMER OPTIONAL

215

215

213

( J3 )

*

203

203

D4

D6

D1

204

204

C1

N.D.

+

THERMOSTAT

(MOUNTED TO

SEC. COIL)

31A

32

H1

H1

(230V)

208/230 60Hz

GAS

SOLENOID

H1

H3

G

CASE

GROUNDING

STUD

TO EARTH

GROUND PER

NATIONAL,

LOCAL OR

OTHER

APPLICABLE

ELECTRICAL

CODES.

H3

(208V)

N.A. DIODES D1, D3, D5 & D7 ARE MOUNTED ON THE OUTSIDE HEATSINK.

N.B. DIODES D2, D4, D6 & D8 ARE MOUNTED ON THE INSIDE HEATSINK,

CUSTOMER VOLTAGE RECONNECTION FOR DUAL VOLTAGE MACHINE

MACHINES ARE SHIPPED FROM FACTORY CONNECTED FOR 230V AS SHOWN. TO CONNECT WELDER FOR

REVERSE OF ABOVE PROCEDURE. SEE INSTRUCTION MANUAL FOR DETAILS.

SLEEVING, REINSTALL CASE SIDE BEFORE CONNECTING INPUT POWER. RECONNECTION TO 230V IS

D3

ON-OFF

SWITCH

S1

FROM TAB TERMINAL H1. REMOVE TAPE SECURING H3 TO LEAD SLEEVING AND CONNECT H3 TO TAB

TERMINAL H1. INSULATE UNUSED H1 LEAD FOR 300V WITH ELECTRICAL TAPE AND SECURE TO LEAD

208V INPUT. DISCONNECT WELDER FROM INPUT POWER, REMOVE CASE SIDE, REMOVE LEAD MARKED H1

GUN CABLE

CONDUCTOR BLOCK

120,000 f

50V

.0047 f

3KV

.0047 f

3KV

CASE

GROUNDING

STUD

RF CHOKE

AS'BLY

4-16-99G

NOTE:

This diagram is for reference only. It may not be accurate for all machines covered by this manual. The

specific diagram for a particular code is pasted inside the machine on one of the enclosure panels.

Advertising