INSTALLATION

SP-175 PLUS

TECHNICAL SPECIFICATIONS – SP-175 Plus

Fuse or

Output Mode

Input Voltage

Breaker Size

Input Amps

Power Cord

RATED

230V/60Hz

40 Super Lag

21/23

50 Amp, 250V,

208V/60Hz

Three-Prong Plug

(NEMA Type 6-50P)

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT CABLE AND FUSE SIZES

Height

Width

Depth

Weight

12.0 in

9.75 in

16.5 in

60 Ibs

305 mm

248 mm

419 mm

27.3 kg

PHYSICAL DIMENSIONS

Standard Voltage/Frequency Input Current

230V/60Hz

21 Amps – Rated Output

208V/60Hz

23 Amps – Rated Output

Duty Cycle Amps Volts at Rated Amperes

30% Duty Cycle @ 230V/60Hz

130

20

30% Duty Cycle @ 208V/60Hz

130

20

Welding Current Range Maximum Open Circuit Voltage Wire Speed Range

Rated DC Output: 25 – 175 amps

33

50-400IPM (1.3-10.2m/min)