Combustible

Combustible

A

D

E

B

Figure 3 - Parallel Installation

Figure 4 - Corner Installation

C

F

B

G

Combustible

Combustible

MODEL CI1000HT IS NOT APPROVED FOR USE WITH DOUBLE

WALL PIPE.

DO NOT INSTALL THE CI1000HT INTO AN ALCOVE OR A CONFINED

SPACE. This unit has not been tested or approved for installation

into a confined space such as an alcove (see the national standard

below).

NFPA 211- latest edition: (Applies to Solid Fuel Burning Appliances,

which are not alcove tested) - Solid fuel-burning appliances shall

not be installed in confined spaces. The space or room shall be of

ample size to allow adequate circulation of heated air. Appliances

shall be so located as not to interfere with the proper circulation

of air within the heated space.

Installing Leg Pads

The four leg pads (included in accessory package), are provided for

placement under the four legs.

COMBUSTIBLE WALL CLEARANCE – USA & Canada

WARNING: It is very important that you observe the minimum

clearances.

There are listed clearances for your stove which were determined in a

Laboratory test using various “classes” of stove pipe or chimney. Mini-

mums are first established for the stove itself and increased based on

how much heat is transferred by each class of pipe.

Position the unit no closer than the minimum clearances to combustible

materials. Check that no overhead cross members in the ceiling or roof

will be cut. Reposition unit if necessary being careful not to move closer

than the minimum clearances.

Single Wall Pipe - CI2000HT

(Not approved for alcove installations)

Using single wall 24 MSG black or 25 MSG blued steel connector pipe

with factory-built chimney listed to either UL 103HT or ULC S629.

Double Wall Pipe - CI2000HT

(For alcove installations, clearances “C” and “F” are not applicable) Use

listed double wall chimney connector or Type L vent pipe to the top of

the stove.

Minimum Clearances to Combustibles - inches (millimeters)

A

18” (457 mm)

D

13” (330 mm)

B

32” (813 mm)

E

20” (508 mm)

C

27” (686 mm)

F

16” (406 mm)

G

35-3/16” (894 mm) This is a reference dimension only

Table 6 (see Figures 3 and 4)

Minimum Ceiling Height for Single wall pipe and double wall pipe instal-

lations and Alcove Installations – 60” (1524 mm) from floor to ceiling

and 29” (737 mm) from stove top to ceiling.

Alcove Installation Clearances - CI2000HT

Alcove Installations Require Double Wall Pipe Only

Use listed double wall chimney connector or Type L vent pipe to the top

of the stove.

Minimum Clearances to Combustibles - inches (millimeters)

A

14-1/2” (368 mm)

D

10” (254 mm)

B

28-1/2” (724 mm)

E

17” (432 mm)

C

18” (457 mm)

F

7” (178 mm)

Table 7 (see Figures 3 and 4)

Note: Alcove clearances cannot be reduced using wall protection. Maxi-

mum alcove depth must be no more than 48” (1220 mm).

Minimum Clearances to Combustibles - inches (millimeters)

A

14-1/2” (368 mm)

D

10” (254 mm)

B

28-1/2” (724 mm)

E

17” (432 mm)

C

N/A

F

N/A

Table 8 (see Figures 3 and 4)

CLEARANCES - MODEL CI2000HT