Lucent Technologies Host-Based Controller Modem AT User Manual

Page 26

Advertising
background image

Host-Based Modem

Data Addendum

AT Command Set

June 15, 1998

Test and Debug AT Commands (continued)

Lucent Technologies Inc.

Version 1.0

26

41

3 digits

0-400

Error Control frame size

42

2 digits

0-FF

Error control link timeouts

X

43

2 digits

0-FF

Error control link NAKs

44

Table 8

0-1

Compression Negotiation Result (Note 7)

X

45

4 digits

0-200

Compression dictionary size (Note 7)

46-4F

Reserved

50

1 digit

0-2

Transmit flow control: 0 = off; 1 = DC1/DC3; 2 = V.24 ckt 106/133

51

1 digit

0-2

Receive flow control: 0 = off; 1 = DC1/DC3; 2 = V.24 ckt 106/133

52

8 digits

0-FFFFFFFF

Transmit characters sent from DTE (Note 8)

53

8 digits

0-FFFFFFFF

Received characters sent to DTE (Note 8)

54

8 digits

0-FFFF

Transmit characters lost (data overrun errors from DTE) (Note 9)

55

8 digits

0-FFFF

Received characters lost (data overrun errors to DTE) (Note 9)

56

8 digits

0-FFFFFFFF

Transmit Frame count, if error control protocol running (Note 8)

X

57

8 digits

0-FFFFFFFF

Received Frame count, if error control protocol running (Note 8)

X

58

8 digits

0-FFFF

Transmit Frame error count, if error control protocol running (Note 9)

X

59

8 digits

0-FFFF

Received Frame error count, if error control protocol running (Note 9)

X

5A-5F

Reserved

60

Tables 9-10

Note 10

Termination Cause

X

61

2 digits

0-FF

Call Waiting event count

62-7F

Reserved for future versions of this specification

80-FF

Reserved for manufacturer proprietary keys

Table 2 - Call Setup Result Codes

Code

Definition

Implemented

0

No previous call (modem log has been cleared since any previous calls)

X

1

No dial tone detected

X

2

Reorder signal detected, network busy

3

Busy signal detected

X

4

No recognized signal detected

X

5

Voice detected

6

Text telephone signal detected (see V.18)

7

Data Answering signal detected (e.g. V.25 ANS, V.8 ANSam)

X

8

Data Calling signal detected (e.g. V.25 CT, V.8 CI)

9

Fax Answering signal detected (e.g. T.30 CED, DIS)

A

Fax Calling signal detected (e.g. T.30 CNG)

B

V.8bis signal detected

C-F

Reserved

Table 6 - gstnModulationSchemeActive from 3.7.2/V.58

Value (hex)

Description

Implemented

0

V.17

1

V.21

2

V.22

3

V.22bis

4

V.23 Constant Carrier (1200/75)

5

V.23 Switched Carrier (half duplex)

6

V.26bis

7

V.26ter

8

V.27ter

9

V.29 HD

A

V.32

X

B

V.32bis

C

V.34

X

D

V.34 HD

E

V.pcm (asymmetric)

F

V.pcm (symmetric)

E-7F

Reserved (V.58)

80

“X2™”

81

“K56FLEX™”

X

82

“V.FC”

83

“V.32terbo”

80-FF

Reserved for mfgs

Advertising