Lexicon PCM92 User Manual

Page 32

Advertising
background image

26

coNtINUoUS coNtRoLLeRS

All PCM92 soft row parameters can be controlled with single, 7-bit control-
lers. Each parameter is controlled with the full controller range, regardless of
the parameter range. For example, if the controller is at the midpoint of its
range (64), the parameter will also be at the midpoint of its range no matter
what the actual number.
Continuous Controllers range from 0 to 127. If the parameter range is less
than 127, then a small controller change might not result in a parameter
update. But the entire range of the parameter can still be accurately con-
trolled. In addition, if the actual range of the parameter is greater than 127,
MIDI control might be somewhat coarse. This is most noticeable with large
delays.

When MIDI is enabled, the PCM92 automatically sends MIDI messages
through the MIDI Out port for soft row parameters and preset loads when-
ever those actions are performed via the front panel controls.

SoFt RoW PARAMeteR/MIdI cc MAP

Soft Row Parameter

MIDI CC

Parameter #1

CC 48

Parameter #2

CC 49

Parameter #3

CC 50

Parameter #4

CC 51

Parameter #5

CC 52

Parameter #6

CC 53

Parameter #7

CC 54

Parameter #8

CC 55

bANK/PReSet MAP

User Bank

Type

Presets

MIDI Bank #

Internal

Mono

1

Mono User Presets 0-127

72

2

Mono User Presets 128-255

73

Stereo

1

Stereo User Presets 0-127

74

2

Stereo User Presets 128-255

75

System

1

System User Presets 0-127

76

2

System User Presets 128-255

77

Advertising