Three measuring modes are available:

infrared laser measurement mode IR.

visible red laser measurement mode RL.

long range visible red laser measurement mode LO.

EDM
Infrared IR

This EDM refers to the infrared laser and the ability to measure
distances to prisms.

EDM
Reflectorless RL

This EDM refers to the visible red laser and the ability to measure
distances without prisms.

EDM
Reflectorless LO

This EDM refers to the visible red laser and the ability to measure
extended distances to prisms.

PinPoint

PinPoint refers to the Reflectorless EDM technology which
enables an increased measuring range with a smaller laser spot
size. Two options are available: R100 and R300.

EGL

Electronic Guide Light

An EGL fitted to an instrument assists with prism targeting. It
consists of two differently coloured flashing lights located in the
instrument telescope housing. The person holding the prism can
align him/herself into the instrument’s line of sight.