LEICA TPS1200 User Manual

Page 173

Advertising
background image

Technical Data

TPS1200

173

Accuracy

Object in shade, sky overcast.
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
The display resolution is 0.1 mm.

Characteristics

Standard
measuring

Standard
deviation,
ISO 17123-4

Measure time,
typical [s]

Measure time,
maximum [s]

Reflectorless
1.5 m - 500 m

3 mm + 2 ppm

3 - 6

12

Reflectorless
>500 m

5 mm + 2 ppm

3 - 6

12

Measuring system R100:

Special frequency system basis 100 MHz 1.5 m

Measuring system R300:

System analyser basis 100 MHz - 150 MHz

Type:

Coaxial, visible red laser class 3R

Carrier wave:

670 nm

Advertising