Troubleshooting & repair, Main transformer test (continued), Warning – Lincoln Electric POWER MIG SVM160-B User Manual

Page 59: Procedure, F-15, Figure f.2 – main transformer test point locations

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-15

F-15

POWER MIG 300

MAIN TRANSFORMER TEST

(continued)

FIGURE F.2 – MAIN TRANSFORMER TEST POINT LOCATIONS

PROCEDURE

The ON/OFF POWER SWITCH will be "hot" during
these tests.

NOTE:

Secondary voltages will vary proportionately

with the primary input voltage.

1. Disconnect the main input power supply to the

machine.

2. Perform the Case Cover Removal procedure.

3. Remove the tool tray with a 5/16 in. nut-driver (3

screws).

TEST INPUT VOLTAGE TO THE MAIN TRANS-
FORMER PRIMARY WINDING

:

4. Confirm the reconnect panel is connected properly

for the correct voltage. See reconnect panel con-
nection diagram located on back of machine above
reconnect door.

5. Test for correct input voltage between L1 lead at the

LINE SWITCH to L2. Voltage tested will vary
depending on the input voltage connection. See
Wiring diagram for test point locations.

* If the voltage is incorrect, check for loose or broken

leads between the reconnect panel and the ON/OFF
POWER SWITCH. Also, test the ON/OFF POWER
SWITCH for proper operation.

* If the voltage is correct, check for the same voltage

at H1 and H4 and at the bottom of the LINE
SWITCH with the switch in the ON position.

* If the voltage is incorrect, check for loose or broken

leads between the reconnect panel and the LINE
SWITCH.

* If the correct voltage is being applied to the main

transformer primary winding, proceed to the table
below for the secondary winding output voltage
tests.

WARNING

50

w

at

ts

50

0

oh

m

s

2520

2530

R1

+

2400/100

+

-

57 VAC

-

+

CONTROL RECTIFIER

80 VDC

OUTPUT

RECTIFIER

MAIN

TRANSFORMER

X6

X5

X4

X3

X1

X2

30 VAC

115 VAC

LOCATED ON
TRANSFORMER
BAFFLE

LOCATED ON FRONT
OF MACHINE'S BASE

LOCATED ON
MACHINE'S BASE
(STORAGE
COMPARTMENT SIDE)

H1

H4

H1

(SHOWN
CONNECTED
FOR 230V)

H4

H3

H2

H5

L2

L1

G

B

W

H1

L1

L2

H4

H1

H4

H3

H5

H2

H1

LINE

SWITCH

RECONNECT PANEL

LOCATED NEXT TO
MAIN TRANSFORMER
(ON WIRE DRIVE SIDE)

LOCATED ON
CHOPPER BOARD
ASSEMBLY

Leads

X1-X2

X3-X4

X5-X6

Description

Power to output

rectifier

Power to fan motor

Power to control

rectifier

Expected Voltage

57 VAC

115 VAC

30 VAC

If the correct voltage is being applied to the main
transformer and one or more of the secondary volt-
ages is missing or incorrect, the main transformer
may be faulty. Replace the main transformer.

Advertising