TROUBLESHOOTING & REPAIR

F-35

F-35

POWER MIG 300

SCOPE SETTINGS

Volts/Div.....................20V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal

TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED

MACHINE LOADED TO 250 AMPS AT 26 VDC

This is a typical DC output voltage waveform generated from a properly operating machine. Note that
each vertical division represents 20 volts and that each horizontal division represents 2.00 milliseconds in
time.

NOTE:

Scope probes connected at the machine output terminals: (+) probe to electrode, (-) probe to work.

20.0 V

2.0 MS/DIV

Advertising