Electrical parts – LG LP091HEM-Y8 User Manual

Page 12

Advertising
background image

- 12 -

Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes

LGE Internal Use Only

2.2.4 SHROUD

1. Remove the axial fan. (Refer to section 2.2.3)
2. Remove the 4 screws which fasten the condenser

with the shroud and the basepan. (See Figure 11)

3. Remove the shroud.
4. Re-install the component by referring to the

removal procedure.

2.3. ELECTRICAL PARTS

2.3.1 OUTDOOR MOTOR

1. Remove the clamp cord and disconnect a wire

housing in control box. (Refer to section 2.1.2)

2. Remove the axial fan. (Refer to section 2.2.3)
3. Remove the 2 screws which fasten the motor.

(See Figure 14)

4. Remove the motor
5. Re-install the component by referring to the

removal procedure, above.

2.3.2 INDOOR MOTOR

(Refer to section 2.2.2)

2.3.3 COMPRESSOR

1. Discharge the refrigerant system using a

refrigerant recovery system.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before venting
the refrigerant. Leave the valve in place after
servicing the system.

2. Disconnect the 3 leads from the compressor.
3. After purging the unit completely, unbraze the

suction and discharge tubes at the compressor
connections.

4. Remove the 3 nuts and the 3 washers which

fasten the compressor. (See Figure 15)

5. Remove the compressor.
6. Re-instill the components by referring to the

removal procedure, above.

2.3.4 CAPACITOR

1. Remove the control box. (Refer to section 2.1.2)
2. Remove 1 screw and disconnect the leads which

connected to the box type capacitor.
(See Figure 16)

3. Remove 1 screw and the clamp which fastens the

can-type capacitor.

4. Disconnect all the leads of capacitor terminals.
5. Re-install the components by referring to the

removal procedure, above.

Figure 13

Figure 14

Figure 15

Figure 16

Advertising