LG LP091HEM-Y8 User Manual

Page 37

Advertising
background image

- 37 -

Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes

LGE Internal Use Only

Note:
The proper subbase must be ordered to obtain the correct
electrical receptacle. (Figure 61)

8. After wiring is complete, mount covers A and F to the

subbase with provided screws. (Figure 58)

9. When installing optional accessories to the subbase, refer

to each installation instruction for that accessory.

Figure 57

Part/Location Identification

A

B

C

D

E

F

Left Front Cover

Right Front Cover

Front Cord Panel

Wall Sleeve Hole Location

Skirting Hole Location

Right Cover Assembly

Wall Sleeve

Cover
Wiring
Access

Subbase
Box Assembly

Low Voltage
Compartment

2-13/16"
(71 mm)

11-13/1

6"

(300

mm)

A

B

F

C

E

D

D

E

Wall Sleeve
(Outdoor Side)

Wall Sleeve
Inside Edge

Back of
Flange "A"

13 3/4"

2 3/4"

2 5/8"

13-7/8" (352 mm)

3-1/16"

(78 mm)

Left End View

Concentric
Knockouts In Bottom

Ground
Screw Location

Receptacle Provided
Inside subbase
Accessory

Top View

Concentric
Knockouts In Rear

Field Wiring
Line Voltage

Field Wiring
Line Voltage

NEMA 6-20R
Receptacle

230/208 VAC Field Schematic

265 VAC Field Schematic

NEMA 6-30R
Receptacle

Voltage

Subbase Receptacle

Unit Plug

NEMA 7-30R
Receptacle

NEMA 7-20R
Receptacle

Front View

20-5/16" (515.5 mm)

2" (50 mm) Max.
Adjustment

4" (101 mm)

2-5/8" (67 mm)

2" (50 mm)

2 3/4"

16"

16"

1-3/8" (35 mm)

Figure 58 - Part/Location Identification

Figure 59 - Dimensions

Figure 60 - Wiring Diagram

Figure 61 - NEMA Plug Configurations