Maximum busy hour traffic supported for a GOS of P.03

Ports

Erlangs

CCS

Minutes

4

1.25

45

75.00

8

3.97

143

238.33

12

7.14

257

428.33

16

10.50

378

630.00

20

13.97

503

838.33

24

17.56

632

1053.33

28

21.19

763

1271.67

32

24.89

896

1493.33

36

28.64

1031

1718.33

40

32.39

1166

1943.33

44

36.19

1303

2171.67

48

40.00

1440

2400.00

52

43.83

1578

2630.00

56

47.69

1717

2861.67

60

51.56

1856

3093.33

64

55.44

1996

3326.67

68

59.33

2136

3560.00

72

63.22

2276

3793.33