Lyngdorf Audio DPA-1 User Manual

Page 31

Advertising
background image

3 1

1 centimeter = 0.3937 in

The fault message ‘Values for delay exceed limits’ is displayed when the difference

between the distance from the speakers closest to, and the speakers furthest from,

the listening position is too big. The biggest difference allowed is 340 cm / 134 in.

If the fault message appears, you can use the following solutions:

(Can be used individually or together to achieve a valid set-up with respect to the delay lengths):

Shorten the distances between your Main and Line channel loudspeakers resulting in a more

compact loudspeaker set-up.

Arrange your loudspeaker set-up and/or your listening position in a more symmetrical set-up.

Trigger Setup

Trigger setup

Trigger setup sets the usage of the trigger output option. If e.g. SDA2175 is connected to drive a sub-

woofer from the Line out, the trigger can be activated and used for switching the SDA2175 On and

Off.

Remote Control

Remote Control

Remote Control set-up makes it possible to activate or de-activate the remote control.

Firmware Versions

Firmware versions

The Firmware Versions menu is used to check the current fi rmware version of your DPA-1 and the Room-

Perfect™ module as well as the RoomPerfect™ serial number.

Factory Reset

Factory Reset

The Factory Reset setting is used to restore all settings, including RoomPerfect, in the DPA-1 to the fac-

tory settings.

If you return to the factory settings all your personal settings will be erased.

Advertising