TROUBLESHOOTING & REPAIR

F-69

F-69

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

MODE BOARD

REMOVAL AND REPLACEMENT (continued)

FIGURE F.29 – SCREW IN CAP

Small Flathead
Screwdriver

18. Replace the mode board.

19. Replace the 1/4” nuts and their washers that

mount the “Hot Start” and “Arc Control”
knobs.

20. Using a small screwdriver replace the two

knobs previously removed. Be sure to place
both potentiometers in the full counter clock-
wise position and position knobs for proper
calibration.

21. Replace the three 5/16” screws previously

removed from the front of the machine located
around the mode board knobs.

22. Replace plugs #J31 and #J34 previously

removed.

23. Replace the four phillips head screws removed

from the front of the machine located around
the two welder output terminals.

24. Replace the six phillips head screws and their

washers from around the input power switch.

25. Using a 5/16” nut driver replace the four

screws previously removed from the front of
the machine

26. Replace the case wraparound cover.