TROUBLESHOOTING AND REPAIR

RETEST AFTER REPAIR

F-94

F-94

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retest a machine:

If it is rejected under test for any reason that requires you to remove any part which could affect the
machine’s electrical characteristics.

If you repair or replace any electrical components:

IDLE AMPS

Input Volts

230VAC

460VAC

575VAC

Maximum Idle Amps

Less Than 1.0 Amp

Less Than 0.5 Amp

Less Than 0.5 Amp

Idle Watts

400 Watts

400 Watts

400 Watts

Note: The machine’s output terminals should be energized but with no external load on the

machine.

PERFORM THE VOLTAGE AND CURRENT CALIBRATION PROCEDURE

This procedure is necessary to insure that the machine is capable of producing output and that the unit is

calibrated correctly.

FAN AS NEEDED (F.A.N.)

The fan should turn on when the machine’s output terminals are energized and stay on for approximately

5 minutes after the output terminals are de-energized.