PROCEDURE

1. Remove input power to the V350-PRO.

2. Using a 5/16” nut driver remove the case wrap-

around cover.

3. Perform the Input Filter Capacitor Discharge

Procedure detailed earlier in this section.

4. Locate the output rectifier modules located behind

the snubber board. See figure F.38.

5. Before the output rectifier modules can be

reached, the Snubber Board Removal
Procedure
must be performed.

6. After the snubber board is removed, remove the

four leads connected to the modules using a 3/16”
allen wrench. These leads are #X4, #X2, #20, #40.
Note their positions for reassembly. See Figure
F.38.

7. Remove the copper plates from the tops of the

modules.