LG RAVENNA RDV33\40 User Manual

Page 16

Advertising
background image

1

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

o

perating

o

ptions

The rocker switch on your Ravenna™ gas insert is used to

turn the burner on and off while the pilot is on. The rocker

switch can be installed in the hole in the right side of the

top surround panel or in the hole in the panel to the left

of the igniter button. The hole in the panel is covered by a

label which must be carefully cut out before installing the

rocker switch. The switch must be disconnected from the

coil of wire to which it is attached, the plastic nut unscrewed

from the back side of the switch, and then the switch can

be inserted into the hole at either location. If the switch is

to be located in the surround, route the wire behind the

igniter bracket and through the hole in the lower right side

of the insert. Attach the three plastic adhesive wire restraints

(found in the bag in the firebox) to the side surround panel.

Feed the wire through these restraints and up to the switch.

Care should be taken to ensure the wire does not come in

contact with the hot surfaces of the firebox. Reconnect the

wires to the switch.
A wall-mounted switch, a millivolt wall thermostat, or a

remote control, can be used to supplement the rocker

switch. The gas valve is powered by millivolts generated by

the pilot assembly. This millivolt system is very sensitive to

electrical resistance, therefore, make sure all connections

are tight, clean, and free from corrosion. Do not splice any

millivolt wires. Consult the table on this Page to determine

the proper gage of wire for the thermostat or wall switch

connections. This table refers to the total length of the wire

(out to the switch and back). The thermostat must be a

millivolt type. A 24-volt furnace thermostat will not work.

Never hook up household current - 120 Volts - to the mil-

livolt system. It is not recommended to hook up any more

than two switches to the insert (for example a rocker switch

and a wall thermostat). Additional switches may affect the

system resistance and increase the chance of the burner not

igniting. Follow the instructions included with the thermostat

or remote control for wiring.

The thermostat, remote control, and rocker switch will turn

the burner on and off independently. Be sure to set the rocker

switch to the “OFF” position when using the thermostat or

remote control and set the thermostat or remote control to

the lowest temperature when you wish to use the rocker

switch only, otherwise one may override the other. If a re-

mote thermostat is to be used with the insert, do not place

the receiver under the firebox.

Millivolt Control

Schematic

Sparker

Pilot Hood

ON/OFF Rocker Switch,

Thermostat, or Remote

Thermostat

Pilot Assembly

Thermocouple

Piezo Igniter

White

Gas Inlet

Pilot Gas Line

Thermopile

Wiring Terminals

Brown

Thermostat Wire

Wire Size

Maximum Length

1 Gage

100 Feet

14 Gage

4 Feet

1 Gage

40 Feet

18 Gage

5 Feet

0 Gage

1 Feet

m

illivolt

C

ontrol

s

ystem

This fireplace operates on a millivolt control system. As

such, no additional power supply is needed for the fireplace

to heat. The pilot assembly contains a thermocouple, that

when heated by the pilot flame, generates electricity (mil-

livolts- mV=1/1000 of a volt) which opens a valve allowing

gas to flow to the pilot assembly. The pilot assembly also

contains a thermopile, that when heated by the pilot flame,

generates electricity that flows to terminal #1 (labeled

THTP) on the gas valve. When the electricity is conducted

from terminal #1 through the on/off switch, thermostat, or

receiver of the remote control to terminal #3 (labeled TH)

on the gas valve, the main burner will ignite.

Figure 18

TH

TP

TH/TP

Advertising