Lynx Professional Grills 27" Free Standing Grill L27PSR-2 User Manual

Page 29

Advertising
background image

29

note:
lynx built-in grills are intended

either for installation in a

built-in enclosure constructed

of non-combustible materials

or for an installation in a built

in enclosure constructed of

combustible material when

installed with a lynx insulating

jacket (liJ).
for non-combustible applica-

tions, the grill drops into the

opening shown in the cutout

detail drawing

(see indeX: “gas

Requirements”)

and hangs from

its counter-top trim. a deck is

not required to support it from

the bottom.
when using the insulated

jacket in a combustible

enclosure, the jacket must be

supported from the bottom by

a ledge on each side or a full

deck beneath the jacket.

(See INDEX: “Gas Requirements”)

pay special attention to the

provisions shown for gas line

hook-up.
the enclosure should have

ventilation holes to prevent

gas build-up in the event of

a leak. the deck ledges and

counter should be flat and

level. (refer to ansi Z21.58

standard for outdoor cooking

gas appliances, section 1.7

enclosures for self contained

lp-gas supply systems)
This grill requires that a 120

volt, 60 hertz, 15 amp gfi

certified outlet be installed by

a qualified electrician.

clearance to com-

bustIble materIals:

minimum clearance from the

sides and back of the grill to

adjacent combustible con-

struction below the top of

unit are 12” from the sides

and back.
dégagement minimal entre

les parois latérales et l’arrière

de l’appariel et la construc-

tion combustible au-dessous

du panneau supérieur de

l’appareil (30 cm à partir des

parois latérales et 30 cm à

partir de l’arrière).
minimum clearance from

sides and back of unit to

adjacent combustible con-

struction extending above the

unit is 18” from the sides and

back.
dégagement horizontal

minimal entre les parois

latérales et l’arrière de

l’appariel et la construction

verticale combustible au-

rear Hood clearance:

A 3 inch clearance is required behind the grill to allow the front

hood to open.
the grill exhausts combustion products and cooking greases to

the back. Never locate the grill where this exhaust will be difficult

to clean.

(3” min)

dessus de l’appareil (45.7 cm

à partir des parois latérales et

45.7 cm à partir de l’arrière).
do not use this appliance

under overhead combustible

surfaces.
ne pas utiliser cet appareil

sous une surface combus-

tible.
a minimum of 6” of clearance

is needed on the left side of

the grill above the counter

top for the motor and skewer.
if the grill is to be placed into

a combustible enclosure, an

approved insulated jacket

is necessary and is available

only from your lynx dealer.

lynx insulated jackets have

been designed and tested

specifically for your Grill.

Advertising