lp connections

make sure the lp cylinder

valve is fully closed. it is

possible for the valve to be

open without releasing gas

but, as soon as you start con-

necting the regulator, gas will

leak from the connection.
insert the regulator inlet into

the cylinder valve and turn the

black coupler clockwise until

the coupler is hand tight. do

not over-tighten this connec-

tion.
To disconnect the coupler, first

make sure the main cylinder

valve is turned off. grasp

the coupler and turn counter

clockwise. the inlet will then

disengage.
always leak-test the connec-

tion after refilling or exchang-

ing lp cylinders.

(see indeX:

“leak test” for further details.)

gas lIne purgIng

you should purge the gas line

of air before attempting to

light the grill.

make sure all grill controls

are in the “off” position.

slowly turn on the main

gas supply.

push in the rotisserie knob

and confirm that the igniter

is glowing. it is furthest

from the fuel source and

will completely purge the

lines. it will take several

seconds for the burner to

light.

hold the knob on for

about 20 seconds to allow

the air in the system to

purge and the burner to

light

wait at least 5 minutes

after shutting off the

control before attempting

to light the burners.

FINAL CHECKS

leaK testIng

leak test procedure:

create a soapy solution

of 1 part soap and 3 parts

water.

Confirm that all control

knobs are in the off

position.

turn on the fuel supply. for

natural gas, turn the valve

handle 1/4 turn to align

with the gas flow.

for l.p., turn the cylinder

valve knob counter

clockwise one full rotation.

apply the soap solution

generously by paint brush

or squirt bottle on all con-

nections and fittings.

if bubbles appear to

“grow” on any of the con-

nections, you have a gas

leak. immediately turn off

the gas supply.

fixing a gas leak

shut off the gas supply

turn all grill controls to

the “on” position to

purge the grill of any gas

build-up, then turn the

controls back “off”.

Danger!

To prevent fire or explosion

hazard, DO NOT smoke or

allow any potential source

of ignition (sparks, electri-

cal arcing, etc) in the area

while performing a leak

test. Leak tests should be

conducted outdoors only.

Never conduct a leak test

using fire or flame.

wash off the soapy solution

with cold water and dry.

tighten the loose joint, or

replace the faulty part with

manufacturer-recommend-

ed replacement parts.

do not attempt to repair

the l.p. cylinder valve if it is

damaged. the only way to

safely resolve a damaged

cylinder is to Replace it.

Repeat the leak test to

ensure that no leaks are

present.

loW Heat burner

adjustment

for maIn brass burners

and sIde burners only!

do not adjust tHe

rotIsserIe burner.

the main brass burners and

side burners on your lynx

grill feature an adjustable low

setting.
fluctuations in gas pressure,

gas conversion and even in

the quality of the gas itself

may affect burner perfor-

mance at the “low” setting.

it could be either too high or

too low.

to adjust the burner

low setting:

make sure the grill is cool.

Remove the racks so you

can see the flames while

adjusting the burners.

light the burner and allow

it to preheat on high for 3

minutes.

turn the burner to “lo”.

Advertising