Gas connections, Natural gas – Lynx Professional Grills 27" Free Standing Grill L27PSR-2 User Manual

Page 33

Advertising
background image

33

GAS CONNECTIONS

the grill is factory set to use

either propane (lp) or natural

gas (nat). it is critical that the

gas you use matches that

which the grill was set up for.

you can verify that by

checking the

rating plate

.

the rating plate is located in

one or more of the following

places:

attached to the underside

of the drip tray

on the heat shield behind

the front panel

the Rating plate lists serial numbers,

model numbers and gas type. this

one is underneath the drip tray.

ensure that the gas supplied

meets with the minimum

pressure requirements. Do not

operate the grill on any gas

other than that for which the

grill has been set.

fuel

wc

max

inlet

wc min

under

full load

nat gas

7 in

4 in

lp

14 in

11 in

Water Column Requirements

Both the regulator and the

manifold orifices have been

tuned for the type of gas

specified on the rating plate.
converting to a different type

of gas requires a conversion

kit, available from lynx or

from your dealer and must be

installed by a qualified techni-

cian.
all installation and all instal-

lation parts must conform to

local codes with the national

electrical code, ansi Z223.1/

nfpa 70 latest edition and

the national fuel gas code,

ansi Z223.1/nfpa 54 in the

u.s and cga-B149.1/.2 in

canada.
canadian installations must

conform to cga-B149.1/.2

natural gas/propane installa-

tion code. (canada)

natural gas

lynx recommends that

only qualified profession-

als perform the required

plumbing on this product.
to ensure satisfactory per-

formance, the gas supply

line must be sized to ac-

commodate the total Btu

requirements of all the gas-

fired equipment that will be

connected to that line.
in no case should pipe less

than 3/4” inside diameter or

1” outside diameter ever be

used to connect this product.

calculate the total Btu

output of all equipment

and refer to “indeX: gas

supply line Runs” for

allowable run distances

for ¾ inch pipe. failure

to meet these minimum

requirements may reduce

performance of the grill

and any other appliances

running on that supply line.

always keep supply line

runs as short as possible.

(see indeX: “Btu output” for

specific model ouputs)

a gas shut-off valve must

be installed in an easily

accessible location by a

qualified plumber.

warning

Never coNNect a gas liNe directly to the grill. a pressure regulator must be

iNstalled oN all gas equipmeNt. all local codes require it aNd lyNx supplies the

correct regulator with your grill. removiNg or failiNg to iNstall the pressure

regulator caN result iN fire aNd serious persoNal iNjury aNd will void the

warraNty.

Advertising