34

Keep threading compound

off of the first two pipe

threads to avoid having

any small pieces of

compound break loose and

clog a burner valve or

orifice. Do not use

threading compound on

any flare fittings.

for

built-in installations, it is rec-

ommended that any flexible

pipe used be kept as short

as possible.

(see indeX: “gas

connections” for typical permanent

hook up.)

for

freestanding

units using

natural gas, lynx strongly

recommends using a quick

disconnect kit.

this quick disconnect kit, part

#lqd, is available from your dealer

.

lp gas

grills set up for lp gas come

equipped with an LP hose/

regulator assembly for con-

nection to a standard 20 lb. lp

cylinder. (Type 1). All fittings

necessary to attach the

assembly to the grill are

included.

Keep

last two

threads

clean

lp cylinder with type 1 valve

connection

permanently plumbed lp con-

nections, such as those in line

with a bulk cylinder, require

a 4/11 regulator. (lynx p/n

30781)

when using the 4/11 regulator

you must ensure that it is set for

the proper fuel type. this is done

by removing the regulator cap and

gasket and looking at the bottom

of the plunger to see what fuel

type is visible. this is the regulator

fuel setting. nat is for natural gas

and lp is for propane gas. the lp

setting can be further identified

by the large diameter disk on the

bottom of the plunger. to change

from one gas to the other simply

push the plunger to the side to

snap it out of the cap, turn the

plunger so it reads the desired gas

type on the bottom, and push the

plunger until it snaps back into

place in the cap then replace the

cap into the regulator.

never connect an unregulated

gas line to the grill.

warning

Do not change the regulator/hose

assembly or use any other assembly

than the one supplied with your

Lynx grill.
Do not attempt to use a 5LP-A

equipped regulator/hose assembly

with a standard 510 POL cylinder/

valve assembly.
Do not store a spare LP-gas cylinder

under or near this appliance
Never fill the cylinder beyond 80

percent full
If the information above is not

followed exactly, a fire causing

death or serious injury may occur.

lp cylinder

requirements

the lp cylinder must be con-

structed and marked in accor-

dance with the specifications

for lp gas cylinders of the u.s.

department of transportation

(dot) and designed for use

with a type 1 system only.
cylinders of free standing

grills must be secured using

the provided cylinder

retention system to avoid

accidental movement.

when exchanging your

cylinder for a refill, exchange

only for a type 1 20lb cylinder

with an over-fill protection

device.
never use a cylinder with a

damaged valve.
a dented or rusty lp cylinder

may be hazardous and should

be avoided. if in doubt, have

it checked by your lp supplier.
always check for leaks after

every lp cylinder change.

(see indeX: “leak test” for further

details.)

always shut off the lp-gas

supply at the cylinder when

the grill is not in use.
cylinders must be stored

outdoors in a well-venti-

lated area out of the reach of

children. if your grill is stored

indoors, the lp cylinder must

be stored outside.

Advertising