LANCOM 7111 VPN – LANCOM 8011 VPN

̈

Chapter 9: Troubleshooting

69

EN

tested (e.g. “DSL1” or “LAN-1”). Pay attention to the correct spelling of the
interfaces. Start the test for the specified interface by clicking on Execute.

Change then to menu item Expert configuration

̈

Status

̈

LAN statis-

tics

̈

Cable test results. The results of the cable test for the individual

interfaces are show up in a list.

The following results can occur:

̈

OK: Cable plugged in correctly, line ok.

̈

open with distance “0m”: No cable plugged in or interruption within less
than 10 meters distance.

̈

open with indication of distance: Cable is plugged in, but defect (short-
circuited) at the indicated distance.

̈

Impedance error: The pair of cables is not terminated with the correct
impedance at the other end.