background image

F-24

TROUBLESHOOTING AND REPAIR

F-24

POWER MIG 255C

4.Verify that the capacitors have completely

discharged with a volt-ohmmeter.

5. Disconnect plugs J6 and J5 control

board. This electrically isolates the
SCR bridge assembly. See Figure F.6.

TEST PROCEDURE

1. Disconnect main AC input power to the

machine.

2. Remove the case top and side panels

with a 3/8 in. nutdriver.

3. Remove the tool tray with a 5/16 in. nut-

driver.

ACTIVE SCR RECTIFIER ASSEMBLY TEST (continued)

FIGURE F.6 — CONTROL BOARD MOLEX PLUG LOCATIONS FOR G3521 PC CONTROL BOARD.

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

J6

J5

J3

J8

J1

J4

J2