Troubleshooting and repair – Lincoln Electric POWER MIG SVM170-A User Manual

Page 93

Advertising
background image

TROUBLESHOOTING AND REPAIR

11. Unplug and label leads X5, X6, X7, X8, and X9.

These leads have connectors near the trans-
former which can be disconnected.

12. Disconnect the output choke lead from the posi-

tive capacitor bank buss using two 1/2 in. open
end wrenches.

13. Remove the other output choke lead from the

positive output terminal using a 1/2 in. wrench.

13. Remove all cable ties, wire mounts, and any har-

ness type that could get in the way during trans-
former removal using wire cutters and screw
driver.

14. Remove the four nuts and washers mounting the

transformer to the floor of the machine using a
1/2 in. wrench.

15. Carefully remove the main transformer and choke

assembly.

16. Reassemble the main transformer and choke

assembly in the reverse order.

F-53

F-53

MAIN TRANSFORMER AND OUTPUT CHOKE