B-3

OPERATION

B-3

USER INTERFACE PUSH BUTTON

The push button on the user interface of the cooler

has two different functions:

Holding the push button in for 3 seconds toggles the

cooler ON and OFF. When the cooler is turned OFF,

the display will shown “oo”. In this condition, the

cooler can only be turned ON again by pressing the

push button for 3 seconds again, or by cycling input

power to the power source. The power source has no

control over the cooler when it is OFF. It begins com-

municating with the cooler when the cooler is turned

ON again. If the cooler is OFF when the power source

is turned OFF, it will begin operation in the ON condi-

tion when the power source is turned on again, and

must be turned OFF if the user does not want the

cooler to operate during welding.

Momentarily pressing the COOL ARC® 35 push but-

ton will begin the torch priming procedure and over-

ride any current cooler operation. The cooler will ramp

up the pump speed to maximum and hold it for 30

seconds to allow the torch to be filled with coolant.

During the priming procedure the temperature and

flow/pressure sensing are disabled. To stop the prim-

ing procedure before the 30 second time limit the

push button must be pressed again - this places the

cooler back into normal operating mode.