E-2

TROUBLESHOOTING

E-2

COOL ARC® 35

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

E43 alarm after initial installation of

power source and cooler, or when

attaching a water cooled torch.

1. Torch water hoses need to be

primed.

2. There is a blockage in the path of

the coolant.

1. A f t e r t u r n i n g t h e s y s t e m O N ,

press the COOL ARC® 35 push

button to begin priming procedure.

2. Verify that the coolant path is

clear – that there are no twists,

k i n k s , o r p i n c h - p o i n t s i n t h e

coolant hoses.