ENGINE CONTROLS (Items 1 through 9)

1. RUN STOP

SWITCH

Toggling the switch to the RUN position energizes the fuel
solenoid for approximately 30 seconds. The engine must be
started within that time or the fuel solenoid will deenergize, and
the switch must be toggled to reset the timer.

2. START PUSHBUTTON

Energizes the starter motor to crank the engine. With the engine
"Run / Stop" switch in the "Run" position, push and hold the Start
button to crank the engine; release as the engine starts. Do not
press while engine is running since this can cause damage to the
ring gear and/or starter motor.

3. HOUR METER

The hour meter displays the total time that the engine has been
running. This meter is a useful indicator for scheduling preventive
maintenance.

4. FUEL LEVEL GAUGE

Displays the level of diesel fuel in the fuel tank.

The operator must watch the fuel level closely to prevent
running out of fuel and possibly having to bleed the system.

5. ENGINE TEMPERATURE GAUGE

The gauge displays the engine coolant temperature.

B-2

OPERATION

B-2

Vantage 500 CUMMINS

CONTROLS AND SETTINGS

All welder and engine controls are located on the case front panel. Refer to Figure B.1 and the explanations that follow.