Troubleshooting, Caution, Problems (symptoms) – Lincoln VANTAGE 500 User Manual

Page 34: Possible areas of misadjustment(s), Recommended course of action, E-4 function problems

Advertising
background image

PROBLEMS

(SYMPTOMS)

Engine goes to low idle but does not stay at
low idle.

No welding output or auxiliary output.

Welder has some/ no output and no control.
Auxiliary output OK

No welding output. Auxiliary output OK.

No auxiliary power.

POSSIBLE AREAS OF

MISADJUSTMENT(S)

1. Faulty Peripheral PCB, Pull Coil/Battery

PCB or Weld Control PCB.

1. Broken lead in rotor circuit.

2. Faulty field diode module.

3. Faulty Weld Control P.C. Board.

4. Faulty rotor.

1. Faulty remote kit.

2. Faulty output control potentiometer.

3. Faulty output control wiring.

4.

Faulty Weld Control PCB, Pull
Coil/Battery PCB or Chopper PCB.

1. WELDING TERMINALS switch in wrong

position, be sure switch is in WELDING
TERMINALS ALWAYS ON position.

2.

Faulty Weld Control PCB, Pull
Coil/Battery PCB or Chopper PCB.

1. Open breakers may need to be reset.

2. Faulty receptacle.

3. Faulty auxiliary circuit wiring.

4. GFCI tripped.

RECOMMENDED

COURSE OF ACTION

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

Vantage 500 CUMMINS

E-4

TROUBLESHOOTING

E-4

FUNCTION PROBLEMS

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln
Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

______________________________________________________________________________________________________________

Advertising