Chapter 4

Fault Management

Cajun M770 Manager User’s Guide

21

Editing Severity Degrees

Severity degrees may be changed for faults on a system-wide basis, or for specific
devices (per IP).

Caution: Do not change the Event Object Identifier of a fault.

Editing Severity Degrees System-Wide

To edit severity degree settings system-wide:

1

Select the enterprise which contains the fault whose settings you want to edit.
A list of the faults under the enterprise appears in the Event Identification
window.

2

Select the fault whose settings you want to edit.

3

Open the Edit menu and select Modify Event.
OR
Double-click the fault whose settings you want to edit. The Event Configurator
window appears.

4

Change the severity setting using the Severity pull-down list.

5

Click OK.

6

Save the changes.
— In HP OpenView and NT-OV: Select File

 Save.

— In NetView: Click Apply.

Editing Severity Degrees for Specific Devices

To edit severity degree settings for specific devices:

1

Select the enterprise which contains the fault whose settings you want to edit.
A list of the faults under the enterprise appear in the Event Identification
window.

2

Select the fault whose settings you want to edit.

3

Copy the fault by opening the Edit menu and selecting Copy Event. The Event
Configurator window appears.

4

Enter a name for the fault in the Event Name field.

5

Set Source to the IP address/es of the specific device/s you want the changes to
be effective on.

6

Change the severity setting using the Severity pull-down list.

7

Click OK.

8

Save the changes.
— In HP OpenView and NT-OV: Select File

 Save.

— In NetView: Click Apply.