MAINTENANCE

D-1

AutoDrive 4R90

ELECTRIC SHOCK can kill.

• Turn the input power OFF at the

welding power source before

installation or changing drive

rolls and/or guides.

• Do not touch electrically live

parts.

• When inching with the gun trigger, electrode

and drive mechanism are "hot" to work and

ground and could remain energized several

seconds after the gun trigger is released.

• Do not operate with covers, panels or guards

removed or open.

• Only qualified personnel should perform main-

tenance work.

----------------------------------------------------------------------

WARNING

SAFETY PRECAUTIONS

ROUTINE MAINTENANCE

To remove the AutoDrive 4R90 for servicing:

(See Figure D.1)

1. Turn off power to the welding power supply and the

entire weld cell.

2. Loosen the thumb screw that secures the torch to

the feed plate.

3. Use a 3/4” (19mm) wrench to remove the electrode

cable from the feed plate.

4. Remove the screw from the bottom rear of the

feeder.

5. Slide the feeder back in the bracket and remove.

6. When reassembling the feeder in the mounting

bracket, make sure all of the studs fully are fully

engaged in the slots. (See Figure D.2)

PERIODIC MAINTENANCE

CALIBRATION SPECIFICATION

FIGURE D.1

FIGURE D.2