Troubleshooting, Caution – Lincoln Electric AUTODRIVE 4R90 User Manual

Page 25

Advertising
background image

E-3

TROUBLESHOOTING

E-3

AutoDrive 4R90

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Variable or "hunting" arc.

The motor overload errors occur.

1. Check for proper size contact.

Make sure the contact tip is not

worn, free of spatter and not melt-

ed.

2. Clean and tighten all electrode

and work connections.

3. Verify the proper polarity is being

used for the weld procedure.

4. Make sure the proper electrode

stick-out is being maintained.

5. Check the gas flow rate and mix-

ture.

6. Verify the gun bushing is tightly

mounted to the wire drive.

7. Verify the gun is tightly mounted

to the gun bushing.

8. Verify the electrode lead is con-

nected to the proper connection

block on the feed head.

9. Inspect the motor for worn brush-

es.

1. Check for sharp bends in the gun

liner and conduit.

2. Examine the contact tip for wear

and proper size. Replace as nec-

essary.

3. Check the gun liner and conduit.

The welding electrode should

slide easily through both.

4. V e ri f y t he pro p e r g u n l in e r is

installed.

5. Reduce the pressure arm setting.