Troubleshooting, Caution – Lincoln Electric AUTODRIVE 4R90 User Manual

Page 24

Advertising
background image

E-2

TROUBLESHOOTING

E-2

AutoDrive 4R90

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

The wire feeder does not feed wire

and the drive rolls do not spin.

The wire feeds erratically.

No shielding gas

Variable or "hunting" arc.

1. Verify the power source is turned

on.

2. Verify the circuit breaker for the

wire feeder on the power source

has not tripped.

3. Verify power is being supplied to

the wire feeder.

1. Verify the correct drive rolls and

inner wire guide are installed in

the wire drive.

2. Check for sharp bends in the gun

liner or conduit.

3. Examine the contact tip for wear

and proper size. Replace as nec-

essary.

4. Check the gun liner and conduit.

The welding electrode should

slide easily through both.

5. V e r i f y t h e p r o p e r g u n l i n er i s

installed.

6. Verify the pressure arms are set

properly. Too much pressure may

crush the wire.

7. Inspect the motor for worn brush-

es.

1. Verify the gas supply is turned on

and not empty.

2. C h e c k t h e g a s ho s e f or c u t s .

Make sure it is not crushed.

3. Verify the shielding gas hose is

connected to the gun bushing or

welding gun.

Advertising