Operation – Lincoln Electric POWER FEED IM849 User Manual

Page 19

Advertising
background image

B-4

OPERATION

B-4

CASE FRONT CONTROL DESCRIPTIONS

1. DUAL DIGITAL DISPLAYS – Bright 7-segment dis-

plays showing welding parameter settings and actu-
al levels while welding.

2. ARC ESTABLISH INDICATOR – Illuminates when

a "true" arc has been established. (Flashes when
open circuit voltage is applied. Not availiable on all
units, upgrade software to include this feature.

3. Status LED - The status LED indicates system sta-

tus. Normal operation is a steady green light.

Note: During normal power-up, the LED may flash
red and/or green as the equipment performs self tests.

LED condition

Definition

Steady green

System okay. The power
source and wire feeder are
communicating normally.

POWER FEED™ 10A CONTROLLER

CASE FRONT CONTROLS

10

11

12

13

1

2

3

4

5

6

7

8

9

Advertising