Troubleshooting, Caution – Lincoln Electric POWER FEED IM849 User Manual

Page 32

Advertising
background image

E-2

TROUBLESHOOTING

E-2

POWER FEED™ 10A CONTROLLER

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Err 006

Err 100

Err 31 Primary overcurrent

Err 32 Capacitor bank "A" under

voltage.

1. The wire feeder has not received

a recognition command from the
power source. Verify the power
source is operating properly
(Status light steady green.)

2. Check control cable for loose or

broken leads.

3. See power source Instruction

Manual.

1. The power source has issued a

shutdown command. Verify the
power source is operating proper-
ly. (Status light steady green.)

2. Check control cable for loose or

broken leads.

3. See power source instruction

Manual.

1. The power source has exceeded

input current limits. Adjust the
welding procedure to reduce the
current draw. The welding proce-
dure may exceed the capacity of
the power source.

2. See the power source Instruction

Manual.

1. The power source input power

may be wired incorrectly. Verify
the power source reconnect
panel wiring matches the input
power.

2. See the power source Instruction

Manual.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.

LINC-NET SYSTEM ERROR CODES

ARCLINK SYSTEM ERROR CODES