Operation, Weld sequence parameter list – Lincoln Electric POWER FEED IM849 User Manual

Page 24

Advertising
background image

B-9

OPERATION

B-9

PARAMETER

Arc Delay Time

Strike Fault Time

Strike WFS

Strike Volts

Restrike Time

Start WFS/Amps

Start Volts

Start Time

Start Arc Force

Upslope Time

Weld WFS/Amps

Weld Volts

Weld Arc Force

Frequency (AC)

Balance (AC)

Offset (AC)

Arc 2 Phase (if applicable)

Arc 2 Balance (if applicable)

Arc 3 Phase (if applicable)

Arc 3 Balance (if applicable)

Arc 4 Phase (if applicable)

Arc 4 Balance (if applicable)

Downslope Time

Crater WFS/Amps

Crater Volts

Crater Time

Crater Arc Force

Burnback Time

UNITS

seconds

seconds

IPM

volts

seconds

IPM/amperes

volts

seconds

amperes

seconds

IPM/amperes

volts

amperes

hertz

percent

percent

degrees

percent

degrees

percent

degrees

percent

seconds

IPM/amperes

volts

seconds

amperes

seconds

RANGE

0-5.0

0-10.0

from weld table*

from weld table*

0-10.0

from weld table*

from weld table*

0-0.5

from weld table*

0-10.0

from weld table*

from weld table*

from weld table*

10-100

25-75

-50.0 - +50.0

0-359

25-75

0-359

25-75

0-359

25-75

0-10.0

from weld table*

from weld table*

0-10.0

from weld table*

0-2.0

DEFAULT VALUE

OFF

OFF

weld mode dependant

weld mode dependant

OFF

weld mode dependant

weld mode dependant

0.1

weld mode dependant

OFF

weld mode dependant

weld mode dependant

weld mode dependant

weld mode dependant

weld mode dependant

0.0

90

50

180

50

270

50

OFF

weld mode dependant

weld mode dependant

OFF

weld mode dependant

0.2

WHERE IS IT SET?

MSP4 - START OPTIONS

MSP4- SETUP Menu

Left Dual Display

Right Dual Display

MSP4 - SETUP Menu

Left Dual Display

Right Dual Display

MSP4 - START OPTIONS

MSP4 - SETUP Menu

MSP4 - SETUP Menu

Left Dual Display

Right Dual Display

MSP4 - SETUP Menu

AC CONTROL

AC CONTROL

AC CONTROL

AC CONTROL

AC CONTROL

AC CONTROL

AC CONTROL

AC CONTROL

AC CONTROL

MSP4 - SETUP Menu

Left Dual Display

Right Dual Display

END OPTIONS

MSP4 - SETUP Menu

END OPTIONS

POWER FEED™ 10A CONTROLLER

WELD SEQUENCE PARAMETER LIST

* Range depends on the Machine Power Source, Literature and Tables supplied with each unit.

Advertising