B-10

OPERATION

B-10

GENERAL SETUP MODE OPTIONS

The Setup Mode can be used to set more general
welding configurations such as travel options or dis-
play configurations and can be used to access diag-
nostic tools.

The POWER FEED™ 10A CONTROLLER can be
configured to display the wire feed speed in inches
per minute or meters per minute, and\or display wire
feed speed or Amps in any weld mode. To access the
wire feed speed units in the Setup Mode, enter into
the Setup Mode by pressing both Mode Select Panel
Pushbuttons simultaneously. The SETUP LED will
illuminate. Turn the Mode Select Panel Knob until
WFS UNITS is listed.

• Press the right Mode Select Button.
• Turn the Knob to toggle between English and Metric.

To set the display to read Wire Feed Speed or Amps,
turn the Mode Select Knob until ARC DISPLAY
MODE is listed.

• Press the right Mode Select Button.
• Turn the Knob to toggle between Amps or WFS.

The POWER FEED™ 10A CONTROLLER can start
and stop travel based on the START and STOP
Pushbuttons, or based on the arc being established or
extinguished. To access the Travel Options in the
Setup Mode, enter into the Setup Mode by pressing
both Mode Select Panel Pushbuttons simultaneously.
The SETUP LED will illuminate. Turn the Mode Select
Panel Knob until TRAVEL OPTIONS is listed.

Pressing the right Mode Select Panel Pushbutton will
enter into the Travel Options. Turning the Mode Select
Panel Knob will toggle between TRAVEL STARTS
and TRAVEL STOPS. Pressing the right Mode Select
Panel Pushbutton, will allow the travel to be set to
start on the START BUTTON or on the ARC STRIKE,
and to stop on the STOP BUTTON or on the ARC
OUT.

This item allows the user to reset the consumable
weight to the initial weight set in Production
Monitoring. This option only appears in the list when
Production Monitoring is installed in the system.

• Press the right Mode Select Button to reset, left to

cancel.

• Press the right Mode Select Button.
• Turn the Knob to toggle between Enabled or

Disabled.

This option allows the user to enable or disable touch
sense when inching down the wire.

Disabled = Default behavior, touch sense is disabled
while inching down.

Enable= Touch sensing is enabled while inching
down.

POWER FEED™ 10A CONTROLLER

P.1

WFS Units

English

SETUP

P.12

Yes

Travel
Options

SETUP

P.12

Travel Starts

Start
Button

SETUP

P.12

Travel Ends

Arc
Out

SETUP

P.2

Arc Display Mode

Amps

SETUP

P.14

Yes

Reset
Wire?

P.15

Touch Sense

Enabled

Advertising